ET 5XX Series Solenoid Dosing Pump
 
 
 
 
 
 
 
 
 
 
 
 
Port
Series
Flow Ltr/Hr
Pressure Bar
0
0.5
1
1.5
2
2.5
2.8
3
3.2
4
6
8
9
10
12
14
16
17
1/8
ET500
53
 
37
 
31
 
 
29
 
27
23
18
16
14
11
7
3
0
1/8
ET500ST
29
 
19
 
16
 
 
11.4
 
12
9
2
0
 
 
 
 
 
1/8
ET508
114
 
84
 
70
 
 
54
 
40
0
 
 
 
 
 
 
 
1/8
ET508LA
5.7
4.2
2.64
1.98
1.44
0.3
0
 
 
 
 
 
 
 
 
 
 
 
1/8
ET508HP
104
82
60
49
39
30
 
19
 
0
 
 
 
 
 
 
 
 
1/8
ET508LP
82
64
44
36
27
15
 
2
0
 
 
 
 
 
 
 
 
 
 
 
SeriesVoltageDuty CyclePower ConsumptionKg
ET500AC230v/50Hz50%53 Watts0.095
ET500STAC230v/50Hz100%25 Watts0.095
ET508AC230v/50Hz60%47 Watts0.095
ET508LAAC230v/50Hz100%25 Watts0.095
ET508HP
AC230v/50Hz
AC120v/60Hz
100%46 Watts0.095
ET508LP
Ac230v/50Hz
Ac120v/60Hz
100%37 Watts0.095
 
Coil:
(AC~) Through a diode incorporated within the coil.
(DC=) Requires the use of a square waves impulse converter
Material: Polyamide (PA) or Polybutylene Terephtalate (PBT) or Polyester (PET)
Insulation: Class II
Thermal Class: F 155C
The coil is provided with a pocket for the thermoswitch which must be wired in series with the power supply to protect the coil from overheating.
Mounting Position: Any
Tube Guide: Polyamide (PA) mineral loaded
Piston and Ring: stainless steel high corrosion resistant
Seals: NBR, EPDM,FKM,MVQ
Sliding Guide: ET500 FKM, ET500ST PTFE, ET508 PTFE
Ambient Temp: 50C, 70C ET508LA
Media Temp: 25C, 60C ET508LA
Fluids: Water and non corrosive media
Suction: 1 meter
Tolerance: all performance apply within +/- 15%
Mounting Brackets: Optional flat and L in metal or rubber foot.